SHANXI HENGXING
HXT Series Iron Oxide Desulfurizers
HXT Series Iron Oxide Desulfurizers
Product Details
1. Application & Performance
Patented in 2008(No.: ZL 2007 1 0139233.X), a new series of iron oxide desulfurizer that structured with itself as the backbone of synthetic iron oxide as the main active ingredient and combine with different accelerants.
Highly targeted and solve the three problems as below:
(a). Solve the too many equipments and replaced frequently problems of H2S dry desulfurization under the conditions of less oxygen or anaerobic.
(b). The problem of difficult to absorb sulfur be solved under the condition of conditions of high level or full carbon dioxide. HXT series hold incomparable advantages than activated carbon under anaerobic conditions which make desulfurization cost reducted a lot.
(c). Solve the traditional desulfurizer easily got hardened while mixed with water for longer time. HXT series hold wet strength up to 25N/CM, effectively prevent harden in contact tower.
HXT series are mainly used for:
(a). Fine or coarse sulfur removal of carbon dioxide, converting gas, industrial exhaust and othergas with high or full carbon dioxide.
(b). Fine or coarse sulfur removal of oxygen-free natural gas and biogas.
Tar, naphthalene, anthracene, quinones, solid micro-particles impurities and oxygen in gas can be removed effectively because of well developed pore structure.
2.Technical Properties & Working Conditions
(a) Main technical specifications
|
Items |
HXT-1 |
HXT-2 |
HXT-3 |
HXT-4 |
|
Appearance (mm) |
Yellow or orange strip, Φ(3-5) × (5-30) |
|||
|
Bulk density (kg/L) |
0.65-0.75 |
0.75-0.85 |
0.75-0.85 |
0.70-0.80 |
|
Strength (N/cm) |
≥40 |
≥60 |
≥50 |
≥50 |
|
Sulfur Capacity (%) |
≥30% |
≥25% |
≥20% |
≥15% |
|
Accumulated sulfur capacity (%) |
≥70% |
≥60% |
≥50% |
≥40% |
|
Pore Volume (ml/g) |
≥0.45 |
≥0.40 |
≥0.40 |
≥0.35 |
|
Porosity (%) |
≥60% |
≥55% |
≥50% |
≥40% |
(b) Main working conditions
|
Items |
HXT-1 |
HXT-2 |
HXT-3 |
HXT-4 |
|
Temperature (°C) |
0-80 |
0-80 |
0-80 |
0-80 |
|
Gas Speed (h-1) |
≤3000 |
≤3000 |
≤1000 |
≤1000 |
|
Pressure (MPa) |
Normal pressure to 8.0 |
|||
|
Humidity |
Unsaturated in working Temperature |
|||
|
Height/Diameter of contact tower |
≥1.5 (better be ≥3.0) |
|||
4. Case Studies & Comparisons
(a). HXT-2 used for enterprise with annual 300,000 tons of urea production capacity

Picture shows dry desulfurization contact tower after converting gas wet desulfurized of this annual 300,000 tons of urea enterprise.
Precision desulfurization requirement achieved, cost dramatically reduced by using HXT-2 type compared with short life cycle activated carbon desulfurizer that used before. Here is the comparison sheet,
|
Case #2: HXT Product vs. Activated Carbon Desulfurizer |
||||||
|
Given Data |
||||||
|
Gas flow rate |
110000 |
m³/h |
|
|||
|
Pressure |
1.8-2.1 |
MPa |
||||
|
Temperature |
28-40 |
°C |
||||
|
H2S concentration |
20 |
ppm |
Outlet H2S concentration |
2 |
≤ppm |
|
|
Comparison - Case Study |
||||||
|
Activated Carbon Desulfurizer |
|
HXT-2 Desulfurizer |
||||
|
Weight needed |
100 |
m³ |
Weight needed |
100 |
m³ |
|
|
Time for changeouts |
86 |
days |
Time for changeouts |
170 |
days |
|
|
Treat cost |
$0.530 |
/km³/day |
Treat cost |
$0.166 |
/km³/day |
|
|
Result |
||||||
|
Cost saving |
$0.364 /km³/day |
|||||
|
Saving rate |
68.7% |
|||||
(b). HXT-1 used for oil associated gas desulfurization at wellhead

Picture shows our technicians inspect & custom service on the spot.
Total 3 contact towers of Φ5*10m and 55m³ loading capacity of each, used for oil associated gas desulfurization. Gas flow rate is 11000m³/day, intlet H2S concentration is 12000-15000ppm, required outlet H2S concentration should be less than 20mg/m3. The changeout rate of HXT-1 is 180days with sulfur capacity upto24-27%.
(c). HXT-4 used for coke oven gas

There are 4 contact towers for coke oven gas desulfurization of a huge iron and steel enterprise, effective volume of every tower is 110m³, 2 run, 2 standby. Can not wet desulfurization. The changeout rate is 270 days by using HXT-4 to treat 100000m³ coke oven gas each day with 4-10g/m³ H2S content and required outlet H2S concentration 20mg/m³ under normal temperature and pressure condition.
Previous
Previous
T502 Series Iron Oxide Desulfurizers