SHANXI HENGXING
T502 Series Iron Oxide Desulfurizers
T502 Series Iron Oxide Desulfurizers
Product Details
1. Application & Performance
With complete independent intellectual property rights, being the larger amount and most wide range used desulfurizer, T502 series have been produced and used for over 37 years.
(a). Continuous natural regeneration can be achieved when O2/H2S≥3, and the working sulfur capacity could be upto 30%.
(b). Mature technology, low price, adopted by over 80% demostic desulfurizer mabufacturers.
Suitable for coke oven gas, biogas, natural gas, chemicals gas and other industrial exhaust gas purification. Good sulfur removal capacity as long as thiols organic sulfur and most ammonia nitrogen compound. Adsorb high carbon chain organic gas (such as tar, naphthalene, anthracene, quinone, etc.) and dust due to porous strip shape.
2. Technical Properties & Working Conditions
(a) Main technical specifications
|
Items |
#T502 |
#T502-2 |
#TG-3 |
#TG-4 |
|
Appearance (mm) |
Yellow or brown strip, Φ(4-12) × (4-50) |
|||
|
Bulk Density (kg/L) |
0.70--0.80 |
0.70--0.80 |
0.75--0.80 |
0.65--0.75 |
|
Strength (N/cm) |
≥50 |
≥50 |
≥40 |
≥40 |
|
1-time anaerobic working sulfur capacity (%) |
≥12% |
≥12% |
≥15% |
≥25% |
|
Accumulated working sulfur capacity (%) |
≥30% |
≥30% |
1-time use |
≥50% |
(b) Main working conditions
|
Items |
#T502 |
#T502-2 |
#TG-3 |
#TG-4 |
|
Temperature (oC) |
0-50 |
0-50 |
0-50 |
0-50 |
|
Gas Speed (h-1) |
≤1000 |
≤800 |
≤800 |
≤800 |
|
Pressure (Mpa) |
Normal pressure to 8.0MPa |
|||
|
Humidity |
≤Saturation vapor pressure |
|||
|
Height/Diameter of contact tower |
≥1.5, better be ≥3.0 |
|||
4. Case Studies & Comparisons
(a). T502 used for shale oil exhaust

Picture shows equipments of shale oil exhaust desulfurization.
80m³ T502 can be loaded in each, total 8 contact towers. Treating 100000m³ gas each hour with inlet H2S concentration <300mg/m³ and outlet <20mg/m³. Can be used through a whole year.
(b). T502 used for coke oven gas —— Case #1

Picture shows desulfurization tower at the annual output of 900,000 tons of coke oven gas manufacturer.
Configured 3 six-layer central discharge contact tower, with air intakes from the central pipe and exhausted after pass through every bed layer. Good quality desulfurizer and high filling requirement are needed for these small resistance contact tower. Volume of each tower is 150m³, inlet H2S concentration is up to 500mg/m³ while outlet is 20mg/m³. T502 can be used for more than a year.
(c). T502 used for coke oven gas —— Case #2

Picture shows desulfurizer changeout scene in a big iron and steel enterprise for coke oven gas contact tower.
With 7 frames that are able to be hung out, total 6 towers, can load 107m3 T502 desulfurizer each. Intake from central and exhaust at side, air just passes through one single 400-600mm layer of desulfurizer. Easy to load and small resistance, but hard to seal and needs good quality desulfurizer and filling ability.
Working conditions:
Pressure: 60kpa,
Temperature: 20-30°C,
Gas flow rate: 60000-70000 m3/h,
Inlet H2S concentration: ≤200mg/m3,
Outlet H2S concentration: ≤20mg/m3,
Changeout period: 1 year.
Previous
Next
Previous
none
Next